The 5800C2W enables retrofitting existing security systems by; converting their wired sensors to Honeywell’s 5800 series wireless technology, and replacing the existing control panel with a LYNX Touch or LYNX Plus series control. The 5800C2W also works with residential VISTA control panels equipped with a wireless RF receiver and keypad. It saves on installation costs, time and materials since there is no need to replace wired devices with individual transmitters. The calibration feature on the 5800C2W solves a frustrating problem, When converting hardwire to wireless zones, the first thing you need to do is find all the resistors. Many times resistors can be in the walls or buried in the window frame. Tried digging those out? Talk about labor! The 5800C2W has a one button calibration. Press it and forget about resistor issues. It will automatically calibrate the value from 2k to 9k. Now that’s a labor saver!
No-Term Alarm Monitoring from $8 a Month. Learn more about easy do-it-yourself business and home security solutions. Read about new security systems features and watch our how to videos for free. Pay Less for Do-It-Together Security with GEOARM!
Monday, January 19, 2015
(ADC-IS-200-LP) Alarm.com Image Sensor- GEOARM
The Image Sensor is a breakthrough product that combines a PIR (Passive Infrared) motion sensor, an integrated still camera, completely wireless communication, and Alarm.com Interactive Services. The Alarm.com Image Sensor offers an entirely new service that is designed to deliver better security through visual verification of alarms and increased engagement through on-demand property views.
The Image Sensor (model ADC-IS-200-LP) is compatible with Simon XTi panels (version 1.0 & up), Simon XT panels(version 1.3 & up), Concord 4.0 panels and requires an Alarm.com module (version 146 & up for XT, 151 & up for XTi, 177 & up for Concord CDMA, 173 & up for Concord HSPA) with an attached Image Sensor daughterboard.
Not only is the image sensor compatible with the wireless GE systems listed above but, it is also compatible with the 2gig go control panel. The only difference in installation is that the you will not need the daughterboard but, you will need to add the 900 mhz transceiver along with the image sensor itself and you will be ready to start capturing images!
- ETL certified for UL 639 and ULC S306
- 35 feet by 40 feet detection coverage area
- Remotely configurable PIR sensitivity
- Pet immunity, etc.
- Easy installation
- Simple panel enrollment
- No broadband required; No router configuration
- Tamper detection, walk test mode, supervision
- Color images
- Night vision
- IR illumination
- Black and white images
- Wireless image transmission to panel
- Wireless image transmission to Alarm.com via cellular networks
Wednesday, October 22, 2014
A new feature of the Honeywell LYNX L5200 and L7000 system
It has been a few weeks since we have said our goodbyes to the Honeywell LYNX L5100 system so we feel this is a good time to inform our readers about an awesome new feature that the 5200 and 7000 system’s bring to the table that the previous LYNX system’s couldn’t.
NIGHT-STAY Mode: Arms Perimeter Only, Plus Selected Zones
• Use NIGHT-STAY mode to provide increased security while staying inside.
• Arms same as STAY mode, but also arms pre selected interior sensors (programmed
by your installer), while other interior sensors are left disarmed.
• Persons entering later can enter through an entry/exit door but they must disarm
the system and must not violate any of the programmed interior zones to avoid
sounding an alarm.
• IMPORTANT: When NIGHT-STAY mode is on, the selected interior zones are
armed and cause an alarm if anyone enters those areas (e.g., waking in the middle
of the night). To avoid sounding an alarm, you must disarm the system before any
activity takes place in those interior zones.
• Arms same as STAY mode, but also arms pre selected interior sensors (programmed
by your installer), while other interior sensors are left disarmed.
• Persons entering later can enter through an entry/exit door but they must disarm
the system and must not violate any of the programmed interior zones to avoid
sounding an alarm.
• IMPORTANT: When NIGHT-STAY mode is on, the selected interior zones are
armed and cause an alarm if anyone enters those areas (e.g., waking in the middle
of the night). To avoid sounding an alarm, you must disarm the system before any
activity takes place in those interior zones.
Tuesday, October 7, 2014
The Honeywell L5100 wireless security system has been discontinued
They say nothing lasts forever, well in this case its absolutely true. They Honeywell LYNX L5100 wireless security system has seen its final day. Honeywell has discontinued the manufacturing of the system for good. If you can remember there was a system released prior to the 5100 system known as the L5000 wireless system. Though the 5000 panel meant well there were quite a few knocks on the panel. The 5000 system had issues with the touchscreen calibration making it difficult for the consumer to navigate the interface, there were also hardware and software issues that would at times leave the system unusable. Then there was the release of the L5100 system which not only fixed the errors of the previous system but, also changed the future of wireless security technology by adding the Honeywell L5100 Z-wave wireless home automation module. With this being said Geoarm security wishes the L5100 system a fond farewell.
If you are interested in finding out whats next for the Honeywell LYNX series take a look at these articles :
Feel free to take a look at our how-to-videos:
Friday, October 3, 2014
How to wire a Tg1 universal communicator
- Push the two indentations on the bottom of the communicator with a tiny flat head screwdriver.
- Once communicator face plate is lifted off look on the bottom left of the communicator you should see 5 pins sticking up.
- Locate the blue bus that comes in the plastic rappers out of the box
- Looking at the front of the bus all the way to the right is your power “red” and to the immediate left of the power will be the area for the ground “black” to be wired.
- Run the wires through the back of the communicator and wire the power into its designated slot as well as the ground.
- Slide the bus onto the 5 pins again making sure the power is all the way to the right and the ground right next to it on the left.
- Run the phone cable through the back as well and make sure it slides into its designated area until it clicks
- Screw in the antenna and you all set!
Thursday, September 11, 2014
In honor of September 11, 2001
Today marks a day I think no American will ever forget 9/11. Geoarm Security would like to take a moment to thank all of the people that were on the scene that day, the police departments, the fire departments, the people that lost their lives, families who this tragic event effected , and the soldiers at war constantly protecting us. Most importantly I would like to appreciate the fact that when America gets hit with an event like this or a natural disaster us Americans always seem to find a way to come together and preserver through the tough times. God Bless America!!!!
Tuesday, September 9, 2014
Modern cellular alarm monitoring
It’s the 21st century
and everything has evolved including wireless security systems and alarm monitoringservices. In the past older, outdated wireless security systems that used
cellular communicators had some bad tendencies. They were infamous for picking
up interference from other local security systems or electrical devices. This
means the alarm systems could be triggered accidentally causing confusion and inconveniences
for everyone. With the evolution of technology wireless security system and monitoring
there are now no longer and interference issues with these types of alarm systems.
This is
excellent news for all the diyers out there! This makes everything so much
easier when installing your wireless alarm system. You no longer have to worry
about having a dedicated land line hooked directly into your alarm system. Not
only is this more convenient for the install but, this also means that you no
longer need to have a dedicated phone line just for you alarm system so you can
save some money.
Cellularalarm monitoring is becoming more and more popular these days not only for the
reasons I listed above but, there are also a few more benefits of using
cellular alarm monitoring services. Cellular alarm combined with a system from
Geoarm Security you can add interactive services and have home automation. Interactive
services are where you can arm and disarm your alarm system from you iPhone or
ipad as long as your system is capable of supporting these features. Homeautomation is another feature which can be used in conjunction with your cellular
monitored wireless security system. This feature is basically where you can
open and close doors with the proper equipment; you can raise or lower the temp
of your thermostat, and even open and close garage doors.